AN9640A(F)/AN9640B(F)
Transport Package
Wooden Case
Product Description
THE SAFETY TESTER IS THE GENERIC TERM TO COVER THE 3 OR 8 TESTS OF THE ELECTRICAL SAFETY STANDARDS, FROM THE INTERNATIONAL STANDARDS
ground bond test (also called bonding test, ground continuity test )
- insulation test (also called high resistance test, megger test)
- hipot test to make a high voltage test (also called dielectric strength test, hipot test, hi-pot test, breakdown test or flash test)
- leakage current measurement (also called line leakage test)
The final purpose of those tests is to validate that the product under test is safe for the end user, and complies with the quality requirements from the Low Voltage Directive (LVD), applicable to the corresponding standards (IEC335, IEC950, IEC601, IEC1010, IEC598, IEC990, IEC204...)
APPLICATION
MANUFACTURER, LABORATORY, HIGH SPEED PRODUCTION, MAINTENANCE, IN ORDER TO COMPLY WITH THE LOW VOLTAGE DIRECTIVE
• IEC 335 household manufacturer (washing machines, coffee machines, fridges, heaters, boilers, …)
• IEC 204 industrial equipment (compressor, electrical tools, …)
• IEC 598 lighting industry (street lights, professional lighting, medical lighting, bulbs, …)
• IEC 601 medical industry (scanners, surgery equipments, X-ray, electrical beds, …)
• IEC 950 information technology industry (modems, satellite receivers, servers, printers,cash dispensers, …)
• IEC 1010 measurement, control and laboratories industry (electrical meters, test & measurement equipment, …)
SPECIFICATION OVERVIEW
FROM LABORATORY TO PRODUCTION TESTING, OUR RANGE COVERS THE FOLLOWING SPECIFICATIONS
• ground bond test up to 64A AC with resistance measurement up to 600mΩ
• insulation test with DC Voltage from 1V up to 1000 VDC (1V steps),500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A
• leakage current measurement in single or three phases, according to all current international standards
• AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.
• power measurement and cos φ measurement
• Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.
• GPIB, RS232, Ethernet, 0-10V, PLC available
• ESRS software for quality purposes, traceability and professional reporting
Spec.
AC Hipot test | |
Booster rated output capacity | AN9640A(F) | 500VA(5000V/100mA)1 | |
AN9640B(F) | 100VA(5000V/20mA) | |
Booster maximum short-circuit current | >200mA | |
Output waveform | Sine wave, <3%(pure resistance,5000V/1mA),<3%(From empty load to full load) | |
distortion and regulation | |
Output voltage setting | Range | 500~5000V | |
Resolution | 5V | |
Accuracy | ±(3%×setting+10V) | |
Frequency setting | Range | 50Hz/60Hz | |
Accuracy | ±0.1%×setting | |
Alarming limits setting | Current upper-limit | 0.10~99.99mA(20.00mA for AN9640B/C(F)) | |
Current lower-limit | 0.00~10.00mA | |
Compensation current setting | Range | 0.00~10.00mA, automatic testing, compensation can be set to ON/OFF | |
Time setting | Range | 1~999s | |
Ramp up time range | 1~100s | |
Accuracy | ±(0.1%×setting+1count) | |
Breakdown current alarm | Range | 0.10~99.99mA(20.00mA for AN9640B/C(F)) | |
Accuracy | ±(3%×reading+3counts) | |
Insulation Resistance test | |
Rated output capacity | 2VA(1000V/2mA) | |
Output voltage regulation | <3%(From no load to full load) | |
Output voltage ripple | <1% | |
Output voltage setting | Range | DC 500Vor1000V | |
Accuracy | ±(3%×setting+3counts) | |
Alarming limits setting | Resistance upper-limit range | 0.0~99.9 MΩ,100~2000MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit ) | |
Resistance lower-limit range | 0.3~99.9 MΩ, 100~2000MΩ | |
Time setting | Range | 1~999s | |
Accuracy | ±(0.1%×setting+1count) | |
Insulation resistance measurement | Range | 0.0~99.9 MΩ, 100~2000 MΩ | |
Accuracy | ≤200MΩ: ±(3%×reading+3counts) | |
|
Remarks:Except 500V and 1000V voltage points, other voltage accuracy are all 10%. Insulation resistance accuracy is under temperature 0~40ºC , humidity 40ºC/(20~75)% RH,otherwise the accuracy will change. | |
Ground Bond Resistance test | |
No load output voltage | <12V | |
Output current setting | Range | 3~30A | |
Accuracy | ±(3%×setting+0.2A) | |
Current frequency setting | Range | Sine waveform 50Hz/60Hz | |
Accuracy | ±0.1%×setting | |
Test time setting | Range | 1~999s | |
Accuracy | ±(0.1%×setting+1count) | |
Result display mode | Ground resistance or voltage | |
Ground resistance display mode: | |
Alarming limits setting | Resistance upper-limit range | 3A≤output current≤10A:10~600 mΩ | |
|
|
Resistance lower-limit range | 0~100 mΩ | |
Compensation resistance setting | Range | 0~200 mΩ, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range | 10~600 mΩ | |
Accuracy | ±(3%×reading+ 5counts) | |
Ground voltage display mode: | |
Alarming limits setting | Voltage upper-limit range | 30~7500 mV | |
| Voltage lower-limit range | 0~3000 mV | |
Compensation voltage setting | Range | 0~1000 mV, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range | 10~7500 mV | |
| Accuracy | ±(3%×reading+ 50mV) | |
DUT power control | |
DUT input power requirements | Leakage current, running power and voltage start test, user shall provide the correct input power input to safety tester, recommend to use AN97 frequency conversion power supply | |
Input voltage, frequency | 0~300V(phase voltage), 45~65Hz | |
Isolation transformer output voltage ratio | Leakage current test | 1.06 times rated voltage | |
Running Power test | 1.00 times rated voltage | |
Voltage start test | 0.85 times rated voltage | |
DUT Capacity | Single phase, AN9640A(F) load capacity is 6 KVA | |
AN9640B(F)/AN9640C(F) load capacity is 2KVA | |
Over current protection | Max current 30A, after the over current 5S,automatically cut off the isolation transformer | |
Interface | |
Remote interface | Standard, foot pedal(start/stop) | |
Alarming lamp interface | Standard, 3 color light(testpassfail) | |
Communication interface | Standard RS232,internet, RS485, GPIB optional | |
97 Power supply control interface | Standard,combine with AN97 series frequency conversion power | |
PLC interface | Optional, start,stop,test,pass,fail output | |
Printer interface | Optional | |
Gross Weight | About 50kg | |
Dimension | With packing | 600(W)x385(H)x820(D) | |
Without packing | 426(W)x 178(H)x 600(D) |
Address:
No. 134 Zhuzhou Rd, Qingdao, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company, Other
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001
Company Introduction:
We Ainuo Intelligent Instrument Co., Ltd are a professional designer and manufacturer of test machines, power supply equipment, automatic test system, etc., were established in 1993. We are expert in supplying solution for institutes of Quality Inspection, Commodity Inspection and Measurement dept & industries of electrical appliance, power supply and motor manufacturing industries.
Ainuo mainly has 10 product series:
1. Photovoltaic and Inverter Test Solution;
2. Battery test solution;
3. Power supply test solution;
4. Household appliance test solution;
5. Motor and transformer test solution;
6. Aviation power supply and test solution;
7. Special power supply and test solution;
8. Electrical safety test solution;
9. Power electronics test solution;
10. Quality Inspection Institute Test Solution.
We have won the long-term trust and cooperation of up to several tens of thousand of clients, such as Haier, Media, Gree, Hisense, Changhong, AOC, GE, Electrolus and so on.
Ainuo mission is to "Be an enterprise with great sense of responsibility in the world"